FeaturesOver current protectionConstant voltage and constant current modeNo external attahmentHigh efficiency, light weight, small volumeThe two channels are automatically connected in series or parallel mode by the switch inside the machinePreset limit current pointsLow pipple and noiseIn series mode, the positive and negative power output can be formedIt is easier to set voltage values by multi-loop potentimetersTwo color four LED digit display voltage, current 

model MPS-3003L-3 MPS-3005L-3
Input voltage 220VAC ± 10% 50Hz ± 2Hz
Rated output voltage 0-30V * 2 / 5V * 1 0-30V * 2 / 5V * 1
Rated output current 0-3A * 2 / 3A * 1 0-5A * 2 / 3A * 1
Operating mode Two independent outputs + one fixed 5V / 3A output
Tandem 0-60V / 3A / 5A
in parallel 0-30V / 6A / 10A
Voltage regulation characteristics
Power effect CV≤0.01% + 5mV CV≤0.2% + 5mV
Load effect CV≤0.01% + 5mV (I≤3A)
Ripple and noise CC≤0.2% + 5mA
CV≤5mV (effective value)
Steady flow characteristics
Power effect CC≤0.2% + 5mA
Load effect CC≤0.2% + 5mA
Ripple and noise ≤3mArms
Parallel mode
Power effect ≤0.01% + 3mV
Load effect ≤0.01% + 3mV (I≤3A) ≤0.02% + 5mV (I> 3A)
Tandem mode
Power effect ≤0.01% + 5mV
Load effect ≤300mV
Positive and negative power supply Slave error≤0.5% + 10mV main circuit (no load, load effect should be added when load≤300mV)
display
Voltage display Three-digit display ± 0.5% + 2d
Current display Three digits display ± 1% + 2d
5V / 3A fixed output power supply
Rated output voltage 5V ± 0.25V
Rated output current 3A
Power effect ≤5mV
Load effect ≤15mV
Ripple and noise ≤2.0mVrms
protection Current limit and short circuit protection
Use environment 0-40 ° C relative humidity≤50RH
operating hours 80% full load continuous working time> 8 hours
Bare metal size 250 * 150 * 380 250 * 150 * 380
Packing size 350 * 250 * 450 350 * 250 * 450
net weight 8.5 9.5
Gross weight 9.2 10.3